1–2
1
Chapter 1: Cyclone III Device Datasheet
Electrical Characteristics
Conditions beyond those listed in Table 1–1 cause permanent damage to the device.
Additionally, device operation at the absolute maximum ratings for extended periods
of time has adverse effects on the device.
Table 1–1. Cyclone III Devices Absolute Maximum Ratings
Symbol
V CCINT
V CCIO
V CCA
V CCD_PLL
V I
I OUT
V ESDHBM
V ESDCDM
T STG
T J
Parameter
Supply voltage for internal logic
Supply voltage for output buffers
Supply voltage (analog) for phase-locked loop
(PLL) regulator
Supply voltage (digital) for PLL
DC input voltage
DC output current, per pin
Electrostatic discharge voltage using the human
body model
Electrostatic discharge voltage using the
charged device model
Storage temperature
Operating junction temperature
Min
–0.5
–0.5
–0.5
–0.5
–0.5
–25
—
—
–65
–40
Max
1.8
3.9
3.75
1.8
3.95
40
±2000
±500
150
125
Unit
V
V
V
V
V
mA
V
V
°C
°C
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
power supply.
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in Table 1–2 and
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as percentage of high-time
over the lifetime of the device.
July 2012 Altera Corporation